Re: displaying a signal in a waveform chart in "slow-motion"
I'm attaching a second Down-Sampling Demo that I think does a more useful job of illustrating the point. This is the "Driver", which generates a 10Hz Sinusoid with amplitude 1 + Gaussian Noise with...
View ArticleRe: Can I transfer data through FIFO in two different myRIO FPGA Targets?
Hi Ahmad, when you already used a "digital" pin to signal a trigger from one myRIO to the other, then why can't you use the very same connection to send information on the "zero degree" or "start of...
View ArticleRe: How do I use a USB hard drive with ext3 starting from scratch
Attached is a snapshot of a few fdisk commands (while in fdisk)
View ArticleRe: Problem in getting accurate measurement using NI 9227
Thanks a lot for your reply 1. Yes it is within calibration2. Its ground referenced signal, I have grounded the shield of the Lapp cables and connected A+ and A- respectively.3. Yes, they are...
View ArticleRe: Digital to analog conversion labview
Yes, but I can not get the correct frequency. If I insert a 100 Hz frequency I obtain 4Hz in an oscilloscope. I don't know how synchronised the samples for be read correctly
View ArticleRe: Importing WSDL to LabView / .NET issue
Thank you for your reply! I tried to pass inputs (see below). Unfortunately, I do not know how to pass GUID to the .NET.Could you please point me in right direction?SessionID...
View ArticleDeployment Completed with Errors on sbRIO-9651 using LabVIEW 2017 SP1
Howdy! I have a question regarding a nagging problem that we've been having lately with our LabVIEW RT Application and sbRIO-9651 SOM controllers. I'm trying to run the top-level RT VI for our...
View ArticleRe: LIN Communication - Slave doesn't answer
Maybe I wrong the slave NAD. Can I sniff the address of the slave? Thank you,Fabio
View ArticleRe: LIN Communication - Slave doesn't answer
ha scritto:Maybe I wrong the slave NAD. Can I sniff the address of the slave? Thank you,Fabio sorry, I read the ID from the NI-XNET Bus Monitor
View ArticleRe: How to write header to CSV automatically ? my vi attached
Hi Ozgur, Thanks for the VI, but it seems that I still need to write the string of header myself right? I need to give that string to the header input.. Or there is no way to do that all...
View ArticleRe: Write to measurement file (.xlsx)- Append new data but in new sheet/table
Yup I also suggest the report generation toolkit. It is free with several versions of LabVIEW (pro and maybe full?) and you can code it to do whatever you want. The express VI Write to Measurement...
View ArticleChange detection event to read DI and AI
Hello, I am having issues using the DAQmx change detection. I am trying to measure 40 temperatures that are hardware multiplexed to 5 AI. The multiplexer board has about a 2Hz clock that increments a...
View ArticleRT data logging and control VI stopped working after upgrading from 2015 to 2017
I have a VI that is deployed onto a cRIO 9118 that is logging data from a few sensors and controlling some outputs. I am running it in scan interface and have it structured properly, with the read in a...
View ArticleLabVIEW 2015 SP1, cRIO-9075, Restart command doesn't restart, hard reset...
Hey All,Early on in discovery here. I compile the RT, and then deploy the compiled startup app to the cRIO successfully. When I do a restart from the utility menu of the project, the cRIO goes away and...
View ArticleHow to build executable file for a project with plugIn subVI?
Hi, I want to build an executable file for my project which has plug in sub VIs. I have below error when I run the .exe file."Error Code: 7, Error Message: Open VI Reference in...
View ArticleRe: Write to measurement file (.xlsx)- Append new data but in new sheet/table
... and the RGT has some good Examples (I wrote one, myself ...). Bob Schor
View ArticleRe: Anyone seen error 1508
Well I am saving the class at the end of each iteration, so that is not the problem.I tried using a .vit instead and that made no difference. Anyone have any other ideas?
View Article"NI microsoft visual C++ 2015 runtime" error during installation from an...
I built an installer for my labview program using labview 2017. When I try to use this installer on a window 7 sp1 machine, I ran into this error message: "The "NI Microsoft Visual C++ 2015 Run-Time...
View ArticleRe: New LabVIEW Signal Processing for Measurement Blog
Very nice! One minor glitch -- your second article ("How Precise is my Measurement?") says "a famous mathematical theorem (Ref 5) relates that the mean value of an arbitrary signal is usually...
View Article